Software and firmware updates for WATTrouter ECO
USB interface driver
https://ftdichip.com/drivers/vcp-drivers/
Note: Please in case of communication problems always upgrade this driver to the newest version!
Regulator firmware and software WATTconfig ECO
The WATTconfig software runs on Windows 7 and later, Ubuntu 16.04 and later, OS X 10.11 El Capitan and later. However, it may work in other OS versions or other Linux distributions.
Since version 2.0 we provide only 64-bit versions of WATTconfig software, up to version 1.4 they are 32-bit. The main reason for this change was MacOS Catalina, which dropped 32-bit support entirely. That's why we decided to move to 64-bit everywhere.
Please always update BOTH software and firmware for your device!
Newest version (November 2024):
Added: The connection via the UDP protocol and the WR BRIDGE service that runs in the module ENcontrol Spotprocessor (at present this module has Czech Only manuals).
Fixed: S-CONNECT: Exception while evaluating wrong index of destination device (S-Connect tab).
Fixed: In the Buy Additional Features window the Order button did not work.
Fixed: Incorrect software behavior in case of restricted access to its configuration directory (in the Windows OS c:\Users\[user]\Documents\SOLAR controls\Wattconfig ECO).
User manual corresponding to this version
WATTconfig ECO 3.3 for Windows:
wattconfig_eco-3.3.16-x86_64.zip
WATTconfig ECO 3.3 for Linux:
wattconfig_eco-3.3.16-x86_64.deb.zip
WATTconfig ECO 3.3 for MAC:
wattconfig_eco-3.3.16-x86_64.dmg.zip
Firmware 3.2.1:
wattrouter_eco_3_2.zip (remains the same)
11. version (April 2024):
Added: Visual indicators of time schedule activity (Time Schedules tab).
Added: Configurable time offsets for the sunrise and sunset time modes (Time Schedules tab).
Added: Option 'Sort outputs by phase and priority' (Other settings tab).
Added: S-CONNECT: Implemented protocol version 2 - new device types, manual station pairing, etc. (S-Connect tab).
Added: S-CONNECT: In the device mapping table, a visual indication of available devices for each device type has been added (S-Connect tab).
Added: WATTconfig Mx MAC application signing and notarization (to pass MACOS Gatekeeper checks).
Modified: Significant speed up of configuration writing via WATTconfig Mx.
Fixed: 3-phase mode settings did not survive device reset (Output settings tab).
Fixed: Unable to set the last output in the Duplicate to dropdown box (Output settings tab).
Fixed: Relay prepend did not work correctly. Unswitched powers of configured higher priorities were incorrectly subtracted from calculated prepend power (3.1 only bug).
Fixed: Vertical scaling issues of the realtime charts (Realtime Chart tab).
Fixed: S-CONNECT: Remote output types stayed indeterminate even after S-CONNECT was turned off and on again.
Fixed: S-CONNECT: Users could not map one input source device to different destination devices (eg. V1-RV1, V1-M1).
Fixed: S-CONNECT: Users could map two or more source devices to the same destination device (eg. V1-RV1, M1-RV1).
Fixed (3.2.1): Low tariff and energy conditions not working in time schedules (Time schedules tab, 3.2 only bug).
User manual corresponding to this version
WATTconfig ECO 3.2 for Windows:
wattconfig_eco-3.2.15-x86_64.zip
WATTconfig ECO 3.2 for Linux:
wattconfig_eco-3.2.15-x86_64.deb.zip
WATTconfig ECO 3.2 for MAC:
wattconfig_eco-3.2.15-x86_64.dmg.zip
Firmware 3.2.1:
wattrouter_eco_3_2.zip
10. version (May 2023):
Added: Sunset today at (Other status info).
Added: Time schedule improvements (Time schedules tab).
Added: Consumption watchdog (Other settings tab).
Added: Added configurable PWM level for the Minimum power field (Output settings tab).
Modified: Optimized output control because of the new time schedule improvements, also fixed few bugs.
Fixed: Maximum power applied incorrectly in PWM output mode (3.0 only bug).
Fixed: The power field in enforced time schedule did not work correctly for PWM mode with nonzero minimum power (3.0 only bug).
Fixed: Power inputs assigned to online chart have incorrect sign in some cases (3.0 only bug).
Fixed: Outputs can be switched remotely if local error is present (3.0 only bug).
Fixed: Glitch when switching SSRs with proportional control (3.0 only bug).
Fixed: The inconsistency of the minimum value in the item 'Maximum power'.
Fixed: The Energy counter in FB input status was incorrectly cleared to zero after device reset and first configuration write.
User manual corresponding to this version
WATTconfig ECO 3.1 for Windows:
wattconfig_eco-3.1.13-x86_64.zip
WATTconfig ECO 3.1 for Linux:
wattconfig_eco-3.1.13-x86_64.deb.zip
WATTconfig ECO 3.1 for MAC:
wattconfig_eco-3.1.13-x86_64.dmg.zip
Firmware 3.1:
wattrouter_eco_3_1.zip
9. version (September 2022):
Added: S-CONNECT protocol (wireless only, output sharing only).
Added: Indicator for external output switching (Output status pane).
Added: S-CONNECT device error indicator (Error and info status).
Added: Duplicate to input field (Output status pane).
Added: Input settings for statistics (Other settings tab).
Added: S-Connect configuration tab.
Added: Logical outputs needed for S-CONNECT protocol.
Added: Ukrainian language.
Removed: SC-Router related error states (Error and info status).
Removed: Measurement source (Input settings tab).
Removed: Logical WLS outputs (Output settings tab).
Removed: Wireless station table (Other settings tab).
Removed: Russian language.
Modified: Connected and maximum power for SSR outputs increased to 100kW (for industrial installations).
Fixed: Bug in relay prepend calculation. Lower prio relay did not prepend when higher prio relay was restricted by time schedule.
Fixed: wrong behavior of power measurement at higher frequencies than 50Hz.
Fixed: Translation bug in Polish: Relay output function swapped with proportional function.
Fixed (WATTconfig 3.0.12): Malfunctioning activation of software extensions in the WATTconfig ECO software.
User manual corresponding to this version
WATTconfig ECO 3.0 for Windows:
wattconfig_eco-3.0.12-x86_64.zip
WATTconfig ECO 3.0 for Linux:
wattconfig_eco-3.0.12-x86_64.deb.zip
WATTconfig ECO 3.0 for MAC:
wattconfig_eco-3.0.12-x86_64.dmg.zip
Firmware 3.0:
wattrouter_eco_3_0.zip
8. version (September 2021):
Fixed: Realtime chart configuration did not survive device restart.
Fixed: Bug in FB power calculation. Wrong value was shown after reset and configuration write.
Fixed: Problem with PWM output mode with minimum power greater than zero. The softstart (meant for heat pumps or vehicle chargers) could run without assigned priority.
Fixed: Malfunctioning inverted output mode (relay, PWM) for WLS outputs.
Fixed: Disabled PWM range for WLS outputs in PWM mode because there is no support for it in WLS communication protocol.
Fixed: Incorrectly used inverted and PWM range options for outputs in remote control mode (with inserted sc-router).
Fixed: Incorrect values in excitation fields in case of local test in remote control mode (with inserted sc-router).
Fixed: There is no need to have purchased PWM feature for the device in case the device is used in remote control mode (with inserted sc-router).
Fixed: PWM frequencies of SSR outputs set to PWM mode did not match the PWM frequency setup in the Other settings tab.
Fixed: PWM frequency setup did not survive device restart.
User manual corresponding to this version
WATTconfig ECO 2.0 for Windows:
wattconfig_eco-2.0.9-x86_64.zip
WATTconfig ECO 2.0 for Linux:
wattconfig_eco-2.0.9-x86_64.deb.zip
WATTconfig ECO 2.0 for MAC:
wattconfig_eco-2.0.9-x86_64.dmg.zip
Firmware 2.1:
wattrouter_eco_2_1.zip
7. version (June 2020):
Added: Realtime chart on Statistics tab.
Added: Output test improvements - output test timeout etc.
Added: Timer status fields for relay output on-delay and off-delay timers.
Added: PWM output range to support PWM/0-10V subrange (eg 1-10V etc.).
Added: 3f mode for outputs.
Added: Weekdays in time schedules.
Added: Import of monthly and yearly statistics from CSV file, available through new buttons in Statistics tab.
Added: Error list to log history of device errors (volatile only, however).
Added: DC source overload error reporting overloading of internal DC source.
Added: Internal DC source voltage field in Other settings tab.
Added: Automatic firmware update to compatible version in Wattconfig.
Modified: Substantially reworked the firmware and software, now based on WATTrouter Mx, uses many of its features supported by the hardware.
Modified: Behavior of SSR outputs during time schedule where its Power field was not set to 100%.
Modified: Output test now respects Maximum power and Full power configuration.
Modified: Inverted option now available for output PWM mode as well.
Modified: Substantially reworked output 3f modes.
User manual corresponding to this version
WATTconfig ECO 2.0 for Windows:
wattconfig_eco-2.0.9-x86_64.zip
WATTconfig ECO 2.0 for Linux:
wattconfig_eco-2.0.9-x86_64.deb.zip
WATTconfig ECO 2.0 for MAC:
wattconfig_eco-2.0.9-x86_64.dmg.zip
Firmware 2.0:
wattrouter_eco_2_0.zip
6. version (June 2018):
Added: The option to restore the erased serial number in the controller from the database on our server has been added to the WATTconfig (recovery is started automatically when an invalid serial number is detected).
Fixed: Incorrect behavior of relay outputs in some cases (sometimes they did not switch off when they should and vice versa).
Fixed: Possible deletion of the serial number memory in the controller by inadvertently running the internal diagnostic command due to a communication error.
Fixed: Some Russian translations in WATTconfig.
User manual corresponding to this version
WATTconfig ECO 1.4 for Windows:
wattconfig_eco_setup_1_4.zip
WATTconfig ECO 1.4 for Linux:
wattconfig-eco-1.4.deb
WATTconfig ECO 1.4 for MAC: not available
Firmware 1.6:
wattrouter_eco_crc_1_6.zip
5. version (September 2017):
Fixed: Bug with premature relay disconnection with lower prio SSR in PWM mode.
Fixed: Wrong counting of consumed and exported energies in statistics, when "sum of all phases" control mode was selected.
User manual corresponding to this version
WATTconfig ECO 1.3 for Windows:
wattconfig_eco_setup_1_3.zip
WATTconfig ECO 1.3 for Linux:
wattconfig-eco-1.3.deb
WATTconfig ECO 1.3 for MAC: not available
Firmware 1.5:
wattrouter_eco_crc_1_5.zip
4. version (November 2016):
Modified: Integration with the SC-Gateway and SC-Router wireless modules further modified.
User manual corresponding to this version
WATTconfig ECO 1.3 for Windows:
wattconfig_eco_setup_1_3.zip
WATTconfig ECO 1.3 for Linux:
wattconfig-eco-1.3.deb
WATTconfig ECO 1.3 for MAC: not available
Firmware 1.4:
wattrouter_eco_crc_1_4.zip
3. version (September 2016):
Added: Integration with the SC-Router wireless module (fully fledged wireless communication).
User manual corresponding to this version
WATTconfig ECO 1.3 for Windows:
wattconfig_eco_setup_1_3.zip
WATTconfig ECO 1.3 for Linux:
wattconfig-eco-1.3.deb
WATTconfig ECO 1.3 for MAC: not available
Firmware 1.3:
wattrouter_eco_crc_1_3.zip
2. version (October 2015):
Added: Integration with the SC-Gateway wireless module.
User manual corresponding to this version
WATTconfig ECO 1.1 for Windows:
wattconfig_eco_setup_1_1.zip
WATTconfig ECO 1.1 for Linux:
wattconfig-eco-1.1.deb
WATTconfig ECO 1.1 for MAC: not available
Firmware 1.2:
wattrouter_eco_crc_1_2.zip
1. version (December 2014):
User manual corresponding to this version
WATTconfig ECO 1.1 for Windows:
wattconfig_eco_setup_1_1.zip
WATTconfig ECO 1.1 for Linux:
wattconfig-eco-1.1.deb
WATTconfig ECO 1.1 for MAC: not available
Firmware 1.1:
wattrouter_eco_crc_1_1.zip